![]() There is no data conversion in the fix, we start from scratch, hopefully for the last time. After updating please delete all other devices from hardware "Motherboard" and use the new ones. The code now looks at the identifier field in the WMI table, which looks like "/intelcpu/0/load/2" or "/ram/data/0". By using nssm () you have the option to restart the program in case of a crash.Įdit: the WMI id's seem to change over time, on some machines after a long time on others very fast, so using the WMI id is not a good option. Windows still thinks the service is ok but the app is no longer running, and the sensors go red in Domoticz. There are cases where openhardwaremonitor crashes, but srvany/instsrv does not report this to the service manager. All of it Im trying to think of what changed that might have caused it and all I can think of is that I. If you want to install openhardwaremonitor as a service, it is recommended to use nssm instead of srvany. The CPU Z error, MSI afterburner being unresponsive, HWmonitor not showing temps. Please delete the "Internal sensors" hardware device from your system. This has later been named "Motherboard" which you should also see. Note: if you were an early adopter of this code (pre 1270), you might have a hardwaredevice "Internal sensors". percentage disk/memory used, cpu core usage). Supported sensors are all sensors of type "Temperature" (e.g. This way if openhardwaremonitor.exe is not running, the sensors will go red in the interface just like any other sensor. Domoticz however checks if the openhardwaremonitor.exe process is present, and if so adds new data to the sensor database. The WMI tables are static, even if openhardwaremonitor is not running the last values remain in the WMI table. At anytime the hardware id or devices can be deleted, but they will be added again when Domoticz picks them up in the WMI tables. They can then be added to the temperature and utility (for load sensors) tabs. On this hardware id the detected sensor devices are added, and they appear in unused devices. Then a new hardware device is added (Motherboard). Once openhardwaremonitor is running and has added data to the WMI table, Domoticz will automatically pick up the supplied data. Domoticz uses those tables to retrieve the data, this way there is no need for specific pc sensor support in Domoticz if openhardwaremonitor supports it, we can support it. When openhardwaremonitor starts to retrieve data, it is also stored in the WMI (Windows Management Instrumentation) tables. Inside the preferences make sure that openhardwaremonitor starts with windows, minimized if you like, etc. Unzip the file anywhere you like (program files recommended), start the executable. To supply this data, open hardware monitor needs to be installed. As of version 1270 it is possible to view internal pc sensor data in Domoticz.
0 Comments
Leave a Reply. |